| Range of product: | Acti 9 |
|---|---|
| Range: | Acti 9 |
| Product name: | Acti 9 iC60 RCBO |
| Product or component type: | Residual current breaker with overcurrent protection (RCBO) |
| Device short name: | IC60 RCBO |
| Device application: | Distribution |
| Poles description: | 2P |
| Number of protected poles: | 2 |
| [In] rated current: | 10 A |
| Network type: | AC |
| Trip unit technology: | Thermal-magnetic |
| Curve code: | B |
| Earth-leakage sensitivity: | 30 mA |
| Earth-leakage protection time delay: | Instantaneous |
| Earth-leakage protection class: | Type A |
| Breaking capacity: | 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-115 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation: | No conforming to IEC 60947-1 |
| Quality labels: | NFIMQVDEKEMA-KEUR |
| Device location in system: | Outgoer |
|---|---|
| Network frequency: | 50 Hz |
| [Ue] rated operational voltage: | 220...240 V AC 50 Hz |
| Magnetic tripping limit: | 3...5 x In |
| Residual current tripping technology: | Voltage independent |
| [Ics] rated service breaking capacity: | 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-17.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 |
| Rated breaking and making capacity: | Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Limitation class: | 3 conforming to EN/IEC 61009-2-1 |
| [Ui] rated insulation voltage: | 500 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage: | 4 kV |
| Surge current: | 250 A |
| Contact position indicator: | No |
| Control type: | Toggle |
| Local signalling: | ON, OFF, fault trip |
| Mounting mode: | Clip-on |
| Mounting support: | DIN rail |
| Comb busbar and distribution block compatibility: | Top or bottom: YESBottom: biconnect |
| 9 mm pitches: | 4 |
| Height: | 86 mm |
| Width: | 36 mm |
| Depth: | 78 mm |
| Product weight: | 273 g |
| Colour: | White |
| Mechanical durability: | 20000 cycles |
| Electrical durability: | 10000 cycles |
| Connections - terminals: | Tunnel type terminal top or bottom 1...35 mm² rigidTunnel type terminal top or bottom 1...25 mm² flexibleTunnel type terminal top or bottom 1...25 mm² flexible with ferrule |
| Wire stripping length: | 12 mm for top or bottom connection |
| Tightening torque: | 2 N.m |
| Earth-leakage protection: | Integrated |