Earth-leakage relay RH99M with manual reset - 0.03..30 A - 0..4.5 s - 240 V  - 56173

Special Price: €219.31 Excl. Tax €219.31 Incl. Tax

Regular Price: €548.27 Incl. Tax

Quick Overview

  • Main
    • range : Vigirex
    • range of product : Vigirex
    • device short name : RH99M
    • product or component type : Residual current protection relay
    • range compatibility : Vigirex RH TOA earth leakage current sensor
      Vigirex RH A earth leakage current sensor
    • relay application : Residual current protection relay

Details - Residual current protection relay - RH99M

  • Complementary
    • earthing system : TT
      TN-S
      IT
    • [Us] rated supply voltage : 220...240 V AC at 50/60 Hz
      220...240 V AC at 400 Hz
    • power consumption in VA : 4 VA
    • type of measurement : Earth fault current internal measurement 80...100 %
    • residual earth-leakage time delay adjustment type : Instantaneous 0.03 A
      Adjustable 9 settings 0.03...30 A 0...4.5 s
    • test function : Remote test
      Local
    • monitoring : Electronics (continuous)
      Power supply (continuous)
      Relay/sensor link (continuous)
    • [Ithe] conventional enclosed thermal current : 8 A
    • minimum load : 10 mA at 12 V
    • product weight : 0.3 kg
    • mechanical robustness : IK protection 2 joules IK07 conforming to EN 50102
      IP protection IP20 conforming to IEC 60529
      IP protection IP30 conforming to IEC 60529
      IP protection IP40 conforming to IEC 60529
      Vibrations 13.2...100 Hz 0.7 g
      Vibrations 2...13.2 Hz +/- 1 mm
      Fire resistance conforming to IEC 60695-2-1
    • earth-leakage protection class : Class AC
      Class A si
    • overvoltage category : IV
    • tamperproof of settings : Protected by sealable cover
    • mounting support : DIN rail
    • height : 97 mm
    • width : 54 mm
    • depth : 74 mm
    • 9 mm pitches : 6
    • connections - terminals : Terminal block auxiliary power supply 0.2...2.5 mm² flexible AWG 24...AWG 12
      Terminal block auxiliary power supply 0.2...2.5 mm² rigid AWG 24...AWG 12
      Screw terminal fault 0.2...2.5 mm² flexible AWG 24...AWG 12
      Screw terminal fault 0.2...4 mm² rigid AWG 24...AWG 12
      Screw terminal relay test and fault reset 0.14...1 mm² flexible AWG 26...AWG 16
      Screw terminal relay test and fault reset 0.14...1.5 mm² rigid AWG 26...AWG 16
      Screw terminal sensor 0.14...1 mm² flexible AWG 26...AWG 16
      Screw terminal sensor 0.14...1.5 mm² rigid AWG 26...AWG 16
      Screw terminal voltage presence 0.2...2.5 mm² flexible AWG 24...AWG 12
      Screw terminal voltage presence 0.2...4 mm² rigid AWG 24...AWG 12
      Terminal block auxiliary power supply 0.25...2.5 mm² flexible AWG 24...AWG 12
      Screw terminal fault 0.25...2.5 mm² flexible AWG 24...AWG 12
      Screw terminal relay test and fault reset 0.25...0.5 mm² flexible AWG 26...AWG 16
      Screw terminal sensor 0.25...0.5 mm² flexible AWG 26...AWG 16
      Screw terminal voltage presence 0.25...2.5 mm² flexible AWG 24...AWG 12
    • wire stripping length : Auxiliary power supply : 7 mm top
      Relay test and fault reset : 5 mm bottom
      Sensor : 5 mm top
      Fault : 8 mm bottom
      Voltage presence : 8 mm bottom
    • tightening torque : Auxiliary power supply : 0.6 N.m top
      Fault : 0.6 N.m bottom
      Relay test and fault reset : 0.25 N.m bottom
      Sensor : 0.25 N.m top
      Voltage presence : 0.6 N.m bottom

Additional Information - RH99M - Vigirex - 56173

Manufacturer Schneider
Code EAN 3303430561736
Plus d'infos
  • Environment
    • ambient air temperature for operation : -35...70 °C
    • ambient air temperature for storage : -55...85 °C
    • electromagnetic compatibility : Conducted and radiated emissions : B conforming to CISPR 11
      Conducted radio-frequency immunity test : 3 conforming to IEC 61000-4-6
      Electrostatic discharge immunity test : 4 conforming to IEC 61000-4-2
      High-energy conducted susceptibility : 4 conforming to IEC 61000-4-5
      Low-energy conducted susceptibility : 4 conforming to IEC 61000-4-4
      Radiated susceptibility : 3 conforming to IEC 61000-4-3
    • electrical shock protection class : Class II
  • Contractual warranty
    • Warranty period : 18 months